KMDA 7676 FL-U BlackPerfection - Induction hob with integrated vapour extraction 
   

KMDA 7676 FL-U BlackPerfection
Induction hob with integrated vapour extraction  with two extra large PowerFlex XL cooking areas for recirculation mode

Price: SGD $ 9,800.00 
KMDA7676 FL-U BlackPerfection

More product information

Induction hob with integrated vapour extraction  with two extra large PowerFlex XL cooking areas for recirculation mode


  • The quietest TwoInOne from Miele – Silence motor  

    Silence motor 

    Extra-quiet: developed by Miele, this motor is 25 % quieter than its predecessor at higher air throughput levels.
  • Flexible installation – ducted recirculation (e.g. with DFKS-UR) or Plug & Play
  • Ample space – 4 large cooking zones incl. 2 PowerFlex XL areas 

    PowerFlex XL 

    Ample space: as the entire depth of the hob can be used, large cookware can be positioned perfectly. 
  • Automatic fan power regulation – Con@ctivity

    Con@ctivity

    Innovative convenience: the cooker hood reacts automatically to settings on the hob.
  • All-black design ensures an elegant appearance

Downloads - KMDA 7676 FL-U BlackPerfection

User manual & Assembly

Description Format Download
Operating instructions accessoriespdf Download
Product Sheetpdf Download

CAD data / BIM data

Description Format Download
3D data RFAzip Download
3D data DWGzip Download
3D data IFCzip Download
3D data RVTzip Download
3D data FBXzip Download

Installation drawings

Installation drawings

Whether you want to replace a household appliance or planning a kitchen - here you will find all the relevant installation diagrams for your Miele appliance.

If you want to download an installation diagram, please click on the appropriate image and the high-resolution version is displayed. To download, click the right mouse button and save the image on your computer.

Please note that the installation and maintenance of our equipment should only be performed by a licensed contractor. For questions, please call us and we will advise you without any obligation!

Explanations

KMDA7676FL-U, KMDA7876FL-U - surface installation, drilling template, 23,8 cm, Installation drawing

Explanations

KMDA7676FL, KMDA7876FL - Installation drawing

1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm

Explanations

KMDA7676FL, KMDA7876FL - Side view lying on top - Installation drawing

①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.

Explanations

KMDA7676FL, KMDA7876FL - Side view flush - Installation drawing

①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.

Explanations

KMDA7676FL, KMDA7876FL - Side view flush+X - Installation drawing

①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 6 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 14 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.

Explanations

KMDA7676FL-U BlackPerfection, KMDA7876FL-U - flush installation, drilling template, Installation depth 23,8 cm

Explanations

KMDA7676FL-U, KMDA7876FL-U - surface installation, 24,8 cm, drilling template, Installation drawing

Explanations

KMDA7676FL, KMDA7876FL - flush - Installation drawing

1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm

Explanations

KMDA7676FL, KMDA7876FL - Side view flush, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 2 Basis - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90

Explanations

KMDA7676FL, KMDA7876FL -Installation variant 3 Basis - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90

Explanations

KMDA7676FL/FR, KMDA7876FL/FR, Plug&Play (Installation drawing)

Explanations

KMDA7676FL, KMDA7876FL - Side view lying on top+X - Installation drawing

①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.

Explanations

KMDA7676FL, KMDA7876FL - Side view lying on top, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².

Explanations

KMDA7676FL, KMDA7876FL - Side view lying on top+X, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 4 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 13 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.

Explanations

KMDA7676FL/FR, KMDA7876FL/FR, Air circulation (Installation drawing)

Explanations

KMDA7676FL-U, KMDA7876FL-U - flush installation, drilling template, Installation depth 24,8 cm, Installation drawing

Explanations

KMDA7676FL, KMDA7876FL - Side view flush+X, Plug&Play - Installation drawing

①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 1 Basis -drawing

1) DFK-AK 90, 2) DFK-R 1000

Explanations

KMDA7676FL, KMDA7876FL - Installation variant 5 Circulating air - drawing

1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum depth of the cabinet is 935 mm.

Image(s) as examples, to illustrate